Editorial Type:
Article Category: Research Article
 | Online Publication Date: 17 Oct 2005
Multi-Resolution Processing for Random Vibration Control
Multi-Resolution Processing for Random Vibration Control
,
,
, and
Page Range: 35 – 40
A typical vibration test for a specimen is to subject it to a specific spectrum of random vibration. This paper proposes multi-resolution processing using a "frequency domain self-tuning" algorithm for application to random vibration control. MATLAB programs simulate two-octave-band and three-octave-band processing for random vibration control. A PC-based, digital signal processing (DSP) board was used to implement two-octave processing. The simulation and practical results are presented.