Editorial Type:
Article Category: Research Article
 | 
Online Publication Date: 05 Oct 2006

Internal Contamination in the Wide Field/Planetary Camera

,
, and
Page Range: 29 – 35
DOI: 10.17764/jiet.2.33.3.x46th3n44hr8k755
Save
Download PDF

Following thermal vacuum/thermal balance testing, a gray haze was discovered on the corners of the Wide Field/Planetary Camera (WF/PC) aperture window. The phenomenon was suggested to be a result of molecular transport from a low outgassing structural adhesive. Detailed analyses, both chemical and analytical, were conducted to assess the formation of the haze. Each material was considered individually, as it was not known if the actual contamination was a result of one, many, or possibly none of the materials considered. Results of the analytical assessment and the comparison with the aforementioned chemical analyses provided incontrovertible evidence as to the cause of the window haze. The resultant cleanup and subsequent elimination of the problem are also addressed.

  • Download PDF